| Assessment Year | 1985 |
|---|---|
| Principal Product | GRAY IRON CASTINGS |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $1 M to 5M |
| # of Employees | 50 |
| Plant Area |
n/a
|
| Annual Production | 1,000,000
lb
|
| Production Hrs. Annual | 2,573
hrs
|
| Location (State) | Rhode Island |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $38,581 | 397,128 |
kWh
|
$0.097 |
| Natural Gas | $12,930 | 1,874 |
MMBtu
|
$6.90 |
| Coal | $1,000 | 250 |
MMBtu
|
$4.00 |
| Wood | $1,350 | 525 |
MMBtu
|
$2.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,559 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,697 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $313 | $259 |
$313
3,224
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,644 | $2,151 |
$3,644
37,515
kWh
|
|
| 03 | 2.4131: Size electric motors for peak operating efficiency | $11,862 | $2,254 |
$11,862
97,304
kWh
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $740 | $602 |
$740
7,620
kWh
|
|
| TOTAL RECOMMENDED | $16,559 | $5,266 |
$16,559
145,663
kWh
|
||
| TOTAL IMPLEMENTED | $4,697 | $3,012 |
$4,697
48,359
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs