Assessment Year | 1985 |
---|---|
Principal Product | PLASTIC PRODUCTS |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 450,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $285,496 | 4,621,923 |
kWh
|
$0.062 |
Natural Gas | $104,511 | 15,145 |
MMBtu
|
$6.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $26,894 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,198 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2443: Re-use or recycle hot or cold process exhaust air | $11,592 | $6,000 | - |
$11,592
-
MMBtu
|
- | |
02 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $9,754 | $56,300 |
$37,200
599,941
kWh
|
$(-23,446.0)
-
MMBtu
|
$(-4,000.0) | |
03 | 2.7231: Use radiant heater for spot heating | $4,696 | $13,000 | - |
$4,696
-
MMBtu
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $852 | $100 |
$852
17,292
kWh
|
- | - | |
TOTAL RECOMMENDED | $26,894 | $75,400 |
$38,052
617,233
kWh
|
$(-7,158.0)
-
MMBtu
|
$(-4,000.0) | ||
TOTAL IMPLEMENTED | $22,198 | $62,400 |
$38,052
617,233
kWh
|
$(-11,854.0)
-
MMBtu
|
$(-4,000.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs