Assessment Year | 1985 |
---|---|
Principal Product | SINTERED METAL PARTS |
NAICS |
n/a
|
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 380 |
Plant Area |
n/a
|
Annual Production | 10,000,000
lb
|
Production Hrs. Annual | 7,056
hrs
|
Location (State) | Massachusetts |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $569,870 | 8,465,123 |
kWh
|
$0.067 |
Natural Gas | $315,887 | 52,715 |
MMBtu
|
$5.99 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,551 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,551 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,776 | $450 |
$1,776
26,377
kWh
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,840 | $756 | - |
$5,840
-
MMBtu
|
|
03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $12,935 | $31,465 |
$7,963
118,992
kWh
|
$4,972
-
MMBtu
|
|
TOTAL RECOMMENDED | $20,551 | $32,671 |
$9,739
145,369
kWh
|
$10,812
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,551 | $32,671 |
$9,739
145,369
kWh
|
$10,812
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs