Assessment Year 2010
Principal Product kitchen cabinet component and parts
NAICS 337110: Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434: Wood Kitchen Cabinets
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 185,000
ft2
Annual Production 5,000,000
units
Production Hrs. Annual 2,080
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $495,714 5,581,600
kWh
Electricity Demand $109,906 12,898
kW-mo/yr
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $485,837 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $20,414

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
01 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $390,835 $2,640,000 $303,340
3,420,096
kWh
$109,906
-
kW-mo/yr
$(-22,411.0)
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $52,285 $50,000 $33,682
378,458
kWh
$18,603
-
kW-mo/yr
-
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $21,204 $35,000 $13,664
153,535
kWh
$7,540
-
kW-mo/yr
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,686 $1,840 $6,884
77,344
kWh
$3,802
-
kW-mo/yr
-
05 2.4221: Install compressor air intakes in coolest locations $2,513 $1,000 $1,678
18,853
kWh
$835
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $7,215 $58,964 $4,718
50,744
kWh
$2,497
-
kW-mo/yr
-
07 2.7135: Install occupancy sensors $1,099 $104 $1,099
12,355
kWh
- -
TOTAL RECOMMENDED $485,837 $2,786,908 $365,065
4,111,385
kWh
$143,183
-
kW-mo/yr
$(-22,411.0)
TOTAL IMPLEMENTED $20,414 $61,804 $13,280
146,941
kWh
$7,134
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs