| Assessment Year | 1984 |
|---|---|
| Principal Product | THERMOFORMED SHEET |
| NAICS |
n/a
|
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $1 M to 5M |
| # of Employees | 68 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 0
hrs
|
| Location (State) | Massachusetts |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $105,459 | 911,782 |
kWh
|
$0.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,925 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,233 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $543 | $650 |
$543
4,689
kWh
|
- | |
| 02 | 2.2444: Use hot process fluids to preheat incoming process fluids | $5,690 | $3,000 |
$5,690
48,945
kWh
|
- | |
| 03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $34,692 | $70,668 |
$70,227
607,268
kWh
|
$(-35,535.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $40,925 | $74,318 |
$76,460
660,902
kWh
|
$(-35,535.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,233 | $3,650 |
$6,233
53,634
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs