| Assessment Year | 2026 |
|---|---|
| Principal Product | Metal Pipes, Tubes, Joints |
| NAICS | 332996: Fabricated Pipe and Pipe Fitting Manufacturing |
| SIC | 3498: Fabricated Pipe and Pipe Fittings |
| Sales Range | $1 M to 5M |
| # of Employees | 35 |
| Plant Area |
75,750
ft2
|
| Annual Production | 124,800
pieces
|
| Production Hrs. Annual | 3,120
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $89,276 | 1,735,700 |
kWh
|
$0.051 |
| Electricity Demand | $104,371 | 7,248 |
kW-mo/yr
|
$14.40 |
| Electricity Fees | $20,598 | - |
|
- |
| TOTAL YEARLY COSTS | $214,245 | |||
| RECOMMENDED SAVINGS* | $50,156 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $39,842 | $5,254 |
$36,559
711,266
kWh
|
$3,283
-
kW-mo/yr
|
|
| 02 | 2.4322: Use or replace with energy efficient substitutes | $1,634 | $1,887 |
$834
16,234
kWh
|
$800
-
kW-mo/yr
|
|
| 03 | 2.4239: Eliminate or reduce compressed air usage | $8,679 | $8,150 |
$8,679
168,856
kWh
|
- | |
| TOTAL RECOMMENDED | $50,156 | $15,291 |
$46,073
896,356
kWh
|
$4,083
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs