ITAC Assessment: LT8406
ITAC logo
ITAC Assessment: LT8406
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Educational Resource
NAICS 712110: Museums
SIC 8412: Museums and Art Galleries
Sales Range $1
M
to 5
M
# of Employees 25
Plant Area 92,000
ft2
Annual Production 74,000
units
Production Hrs. Annual 1,500
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $207,351 2,990,700
kWh
Electricity Demand $81,508 6,423
kW-mo/yr
Waste Disposal Costs
Water Usage $2,602 291
Tgal
Water Disposal $2,890 291
Tgal
TOTAL YEARLY COSTS $294,350
RECOMMENDED SAVINGS* $105,066 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $13,584 $13,792 $12,966
187,919
kWh
$617
-
kW-mo/yr
-
02 2.2691: Shut off cooling if cold outside air will cool process $89,448 - $88,728
1,285,910
kWh
- $720
03 2.7442: Keep doors and windows shut when not on use $1,624 $750 $670
9,708
kWh
$954
-
kW-mo/yr
-
04 2.7444: Close holes and openings in building such as broken windows $410 $360 $351
5,084
kWh
$60
-
kW-mo/yr
-
TOTAL RECOMMENDED $105,066 $14,902 $102,715
1,488,620
kWh
$1,631
-
kW-mo/yr
$720
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs