Assessment Year | 1995 |
---|---|
Principal Product | Doorlock Hardware |
NAICS |
n/a
|
SIC | 3429: Hardware, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 242 |
Plant Area |
150,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $705,500 | 7,839,097 |
kWh
|
$0.090 |
Natural Gas | $199,971 | 30,579 |
MMBtu
|
$6.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,188 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,317 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,065 | $7,025 |
$4,065
45,135
kWh
|
- | - | - | |
02 | 2.7135: Install occupancy sensors | $4,440 | $4,080 |
$4,440
49,238
kWh
|
- | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,459 | $2,045 |
$1,459
16,120
kWh
|
- | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $3,986 | $3,171 |
$5,616
62,427
kWh
|
$(-1,630.0)
-
MMBtu
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,491 | $985 |
$1,491
16,706
kWh
|
- | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $642 | $2,508 |
$642
7,034
kWh
|
- | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $6,033 | $7,315 |
$6,033
67,116
kWh
|
- | - | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $17,964 | $3,807 |
$17,964
199,590
kWh
|
- | - | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $913 | $400 | - |
$913
-
MMBtu
|
- | - | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $993 | - |
$993
16,706
kWh
|
- | - | - | |
11 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $14,317 | $6,540 | - | - |
$14,317
-
lb
|
- | |
12 | 3.1162: Use less wasteful packaging | $2,885 | $760 | - | - | - | $2,885 | |
TOTAL RECOMMENDED | $59,188 | $38,636 |
$42,703
480,072
kWh
|
$(-717.0)
-
MMBtu
|
$14,317
-
lb
|
$2,885 | ||
TOTAL IMPLEMENTED | $52,317 | $34,705 |
$37,087
417,645
kWh
|
$913
-
MMBtu
|
$14,317
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs