| Assessment Year | 2024 |
|---|---|
| Principal Product | Education |
| NAICS | 611110: Elementary and Secondary Schools |
| SIC | 8211: Elementary and Secondary Schools |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
920,000
ft2
|
| Annual Production | 1,310
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $173,774 | 2,858,400 |
kWh
|
$0.061 | |
| Electricity Demand | $796 | 290 |
kW-mo/yr
|
$2.75 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,241 | 1,481 |
Tgal
|
$1.51 | |
| Water Disposal | $10,041 | 2,135 |
Tgal
|
$4.70 | |
| TOTAL YEARLY COSTS | $186,852 | ||||
| RECOMMENDED SAVINGS* | $10,325 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,032 | $32,765 |
$7,163
117,820
kWh
|
$1,869
-
kW-mo/yr
|
|
| 02 | 2.7444: Close holes and openings in building such as broken windows | $1,051 | $2,000 |
$1,027
16,891
kWh
|
$24
-
kW-mo/yr
|
|
| 03 | 2.7135: Install occupancy sensors | $243 | $317 |
$243
3,994
kWh
|
- | |
| TOTAL RECOMMENDED | $10,325 | $35,082 |
$8,432
138,704
kWh
|
$1,893
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs