| Assessment Year | 1988 |
|---|---|
| Principal Product | STEEL FRAMES & FIBERGLASS |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 300
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $64,977 | 1,016,706 |
kWh
|
$0.064 |
| Natural Gas | $257 | 37 |
MMBtu
|
$6.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,194 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,021 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $88 | $135 |
$88
1,465
kWh
|
- | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $113 | $50 |
$113
1,758
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $68 | $53 |
$79
1,172
kWh
|
- | $(-11.0) | |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $9,060 | $3,200 |
$9,060
181,712
kWh
|
- | - | |
| 05 | 2.7261: Install timers and/or thermostats | $1,541 | $600 |
$953
17,292
kWh
|
$588
-
MMBtu
|
- | |
| 06 | 2.6124: Establish equipment maintenance schedule | $324 | $100 |
$324
6,448
kWh
|
- | - | |
| TOTAL RECOMMENDED | $11,194 | $4,138 |
$10,617
209,847
kWh
|
$588
-
MMBtu
|
$(-11.0) | ||
| TOTAL IMPLEMENTED | $2,021 | $888 |
$1,444
26,377
kWh
|
$588
-
MMBtu
|
$(-11.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs