Assessment Year | 2000 |
---|---|
Principal Product | Hydraulic Iron Workers and Circular Cold Saws |
NAICS |
n/a
|
SIC | 3542: Machine Tools, Metal Forming Types |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
108,500
ft2
|
Annual Production | 1,740
pieces
|
Production Hrs. Annual | 3,380
hrs
|
Location (State) | South Dakota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $112,701 | 1,937,280 |
kWh
|
$0.058 |
Electricity Demand | $340 | 48 |
kW-mo/yr
|
$7.08 |
Electricity Fees | $7,129 | - |
|
- |
LPG | $19,967 | 2,049 |
MMBtu
|
$9.74 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,303 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,062 | $246 |
$1,062
18,464
kWh
|
- | - | - | - | - | - | |
02 | 2.2515: Use optimum thickness insulation | $496 | $316 |
$496
8,499
kWh
|
- | - | - | - | - | - | |
03 | 2.7135: Install occupancy sensors | $850 | $1,512 |
$850
14,654
kWh
|
- | - | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,000 | $2,943 |
$1,000
17,292
kWh
|
- | - | - | - | - | - | |
05 | 3.6124: Burn waste oil for heat | $5,018 | $1,695 | - |
$1,085
-
MMBtu
|
$3,933
-
gal
|
- | - | - | - | |
06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $1,398 | $4,230 | - | - | - |
$1,398
-
lb
|
- | - | - | |
07 | 3.8142: Distill contaminated solvents for reuse | $3,694 | $4,083 |
$(-47.0)
(-879)
kWh
|
- |
$2,131
-
gal
|
- | $(-2,860.0) | - | $4,470 | |
08 | 4.211: Consider use / purchase of bulk materials where possible | $5,929 | $12,962 | - | - | - | - | - | - | $5,929 | |
09 | 4.515: Install shelves / racks to utilize unused space | $600 | $1,288 | - | - | - | - | - | $600 | - | |
TOTAL RECOMMENDED | $20,047 | $29,275 |
$3,361
58,030
kWh
|
$1,085
-
MMBtu
|
$6,064
-
gal
|
$1,398
-
lb
|
$(-2,860.0) | $600 | $10,399 | ||
TOTAL IMPLEMENTED | $17,303 | $23,217 |
$2,015
34,877
kWh
|
$1,085
-
MMBtu
|
$6,064
-
gal
|
- | $(-2,860.0) | $600 | $10,399 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs