| Assessment Year | 1988 |
|---|---|
| Principal Product | POLYETHYLENE FILM |
| NAICS |
n/a
|
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 31 |
| Plant Area |
n/a
|
| Annual Production | 13,000,000
lb
|
| Production Hrs. Annual | 8,520
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $307,006 | 5,638,042 |
kWh
|
$0.054 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $15,254 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $324 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,190 | $87 |
$1,230
27,257
kWh
|
$(-40.0) | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $324 | - |
$324
7,034
kWh
|
- | |
| 03 | 2.2511: Insulate bare equipment | $13,020 | $2,700 |
$13,020
316,530
kWh
|
- | |
| 04 | 2.7261: Install timers and/or thermostats | $720 | $330 |
$720
17,585
kWh
|
- | |
| TOTAL RECOMMENDED | $15,254 | $3,117 |
$15,294
368,406
kWh
|
$(-40.0) | ||
| TOTAL IMPLEMENTED | $324 | - |
$324
7,034
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs