| Assessment Year | 1987 |
|---|---|
| Principal Product | PLASTIC BAGS |
| NAICS |
n/a
|
| SIC | 2673: Plastics, Foil, and Coated Paper Bags |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 70,000,000
lb
|
| Production Hrs. Annual | 8,664
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $755,814 | 15,196,952 |
kWh
|
$0.050 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,451 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $800 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $331 | $128 |
$331
7,620
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,320 | $9,600 |
$2,680
61,547
kWh
|
$640 | |
| 03 | 2.7261: Install timers and/or thermostats | $800 | $350 |
$800
20,223
kWh
|
- | |
| TOTAL RECOMMENDED | $4,451 | $10,078 |
$3,811
89,390
kWh
|
$640 | ||
| TOTAL IMPLEMENTED | $800 | $350 |
$800
20,223
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs