| Assessment Year | 1987 |
|---|---|
| Principal Product | PROCESSED CHICKEN |
| NAICS |
n/a
|
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $10 M to 50M |
| # of Employees | 300 |
| Plant Area |
n/a
|
| Annual Production | 26,000,000
lb
|
| Production Hrs. Annual | 3,380
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $65,632 | 1,424,971 |
kWh
|
$0.046 |
| Natural Gas | $92,235 | 23,424 |
MMBtu
|
$3.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,289 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,899 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,400 | $600 | - |
$3,400
-
MMBtu
|
|
| 02 | 2.2414: Use waste heat from hot flue gases to preheat | $3,390 | $9,380 |
$(-460.0)
(-15,826)
kWh
|
$3,850
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $330 | $157 |
$330
6,448
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $248 | $533 |
$248
4,689
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $239 | - |
$239
4,689
kWh
|
- | |
| 06 | 2.7261: Install timers and/or thermostats | $682 | $150 |
$528
16,999
kWh
|
$154
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,289 | $10,820 |
$885
16,999
kWh
|
$7,404
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,899 | $1,440 |
$1,345
32,825
kWh
|
$3,554
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs