| Assessment Year | 1985 |
|---|---|
| Principal Product | CENTRIFUGAL PUMPS |
| NAICS |
n/a
|
| SIC | 3561: Pumps and Pumping Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
n/a
|
| Annual Production | 550
pieces
|
| Production Hrs. Annual | 6,700
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $337,043 | 6,684,643 |
kWh
|
$0.050 |
| Natural Gas | $8,061 | 1,759 |
MMBtu
|
$4.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $1,590 | $4,500 | - |
$1,590
-
MMBtu
|
- | |
| 02 | 2.2514: Cover open tanks | $1,600 | $216 |
$1,600
38,101
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,890 | $9,540 |
$33,660
656,506
kWh
|
- | $(-7,770.0) | |
| 04 | 2.7261: Install timers and/or thermostats | $2,625 | $450 |
$1,790
43,083
kWh
|
$835
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $31,705 | $14,706 |
$37,050
737,690
kWh
|
$2,425
-
MMBtu
|
$(-7,770.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs