Assessment Year | 1985 |
---|---|
Principal Product | CENTRIFUGAL PUMPS |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 550
pieces
|
Production Hrs. Annual | 6,700
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $337,043 | 6,684,643 |
kWh
|
$0.050 |
Natural Gas | $8,061 | 1,759 |
MMBtu
|
$4.58 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,705 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $1,590 | $4,500 | - |
$1,590
-
MMBtu
|
- | |
02 | 2.2514: Cover open tanks | $1,600 | $216 |
$1,600
38,101
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,890 | $9,540 |
$33,660
656,506
kWh
|
- | $(-7,770.0) | |
04 | 2.7261: Install timers and/or thermostats | $2,625 | $450 |
$1,790
43,083
kWh
|
$835
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $31,705 | $14,706 |
$37,050
737,690
kWh
|
$2,425
-
MMBtu
|
$(-7,770.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs