| Assessment Year | 2026 |
|---|---|
| Principal Product | Bolted Storage Tank |
| NAICS | 332420: Metal Tank (Heavy Gauge) Manufacturing |
| SIC | 3443: Fabricated Plate Work (Boiler Shops) |
| Sales Range | $5 M to 10M |
| # of Employees | 35 |
| Plant Area |
34,725
ft2
|
| Annual Production | 40
pieces
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $37,801 | 439,218 |
kWh
|
$0.086 | |
| Electricity Demand | $40,874 | 2,337 |
kW-mo/yr
|
$17.49 | |
| Natural Gas | $14,175 | 997 |
MMBtu
|
$14.22 | |
| Fuel Oil #1 | $5,900 | 316 |
MMBtu
|
$18.67 | |
| Fuel Oil #2 | $9,900 | 843 |
MMBtu
|
$11.74 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,442 | 3,102 |
Tgal
|
$0.79 | |
| TOTAL YEARLY COSTS | $111,092 | ||||
| RECOMMENDED SAVINGS* | $116,374 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $1,212 | $25 |
$1,212
14,096
kWh
|
- | - | |
| 02 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $796 | $300 |
$796
9,256
kWh
|
- | - | |
| 03 | 2.7211: Clean and maintain refrigerant condensers and towers | $746 | $392 |
$746
8,676
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,368 | $2,575 |
$1,161
13,498
kWh
|
$1,207
-
kW-mo/yr
|
- | |
| 05 | 2.7425: Clean or color roof to reduce solar load | $3,125 | $12,153 |
$3,125
36,337
kWh
|
- | - | |
| 06 | 4.652: Replace existing equipment with more suitable substitutes | $70,474 | $710,000 |
$2,414
28,080
kWh
|
- | $68,060 | |
| 07 | 2.9114: Use solar heat to make electricty | $37,653 | $526,500 |
$37,653
437,832
kWh
|
- | - | |
| TOTAL RECOMMENDED | $116,374 | $1,251,945 |
$47,107
547,775
kWh
|
$1,207
-
kW-mo/yr
|
$68,060 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs