Assessment Year | 2025 |
---|---|
Principal Product | Food Seasonings |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 40 |
Plant Area |
56,355
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 4,290
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $145,286 | 1,665,040 |
kWh
|
$0.087 | |
Electricity Demand | $20,552 | 2,773 |
kW-mo/yr
|
$7.41 | |
Natural Gas | $195,293 | 55,485 |
MMBtu
|
$3.52 | |
Waste Disposal Costs | |||||
Water Usage | $7,444 | 1,107 |
Tgal
|
$6.72 | |
Solid Waste (non-haz) | $13,580 | 48,500 |
lb
|
$0.28 | |
TOTAL YEARLY COSTS | $382,155 | ||||
RECOMMENDED SAVINGS* | $79,584 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $16,005 | - | - | - |
$13,580
-
lb
|
$2,425 | |
02 | 2.7261: Install timers and/or thermostats | $13,011 | $50 |
$13,011
149,559
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,367 | $3,470 |
$2,722
31,291
kWh
|
$645
-
kW-mo/yr
|
- | - | |
04 | 2.7425: Clean or color roof to reduce solar load | $4,606 | $17,913 |
$4,606
52,942
kWh
|
- | - | - | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $4,478 | $39,636 |
$4,478
51,480
kWh
|
- | - | - | |
06 | 2.9114: Use solar heat to make electricty | $38,117 | $526,500 |
$38,117
438,122
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $79,584 | $587,569 |
$62,934
723,394
kWh
|
$645
-
kW-mo/yr
|
$13,580
-
lb
|
$2,425 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs