Assessment Year | 2025 |
---|---|
Principal Product | Sodium Silicates |
NAICS | 325180: Other Basic Inorganic Chemical Manufacturing |
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 13 |
Plant Area |
60,077
ft2
|
Annual Production | 73,076,923
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $68,552 | 1,156,000 |
kWh
|
$0.059 | |
Electricity Demand | $35,618 | 2,182 |
kW-mo/yr
|
$16.32 | |
Natural Gas | $524,092 | 188,432 |
MMBtu
|
$2.78 | |
Waste Disposal Costs | |||||
Solid Waste (non-haz) | $12,000 | 48,000 |
lb
|
$0.25 | |
TOTAL YEARLY COSTS | $640,262 | ||||
RECOMMENDED SAVINGS* | $139,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,765 | $200 |
$4,765
80,758
kWh
|
- | - | - | - | |
02 | 2.7261: Install timers and/or thermostats | $287 | $50 |
$287
4,865
kWh
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,945 | $450 |
$1,406
23,827
kWh
|
$539
-
kW-mo/yr
|
- | - | - | |
04 | 3.5314: Use in-process recycling whenever possible | $24,480 | $14,000 | - | - | - |
$12,000
-
lb
|
$12,480 | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $28,682 | $21,000 |
$28,682
486,135
kWh
|
- | - | - | - | |
06 | 2.1133: Adjust burners for efficient operation | $62,919 | $100,000 | - | - |
$62,919
-
MMBtu
|
- | - | |
07 | 2.2223: Enhance sensitivity of temperature control and cutoff | $2,760 | $4,900 |
$1,542
26,140
kWh
|
- |
$1,218
-
MMBtu
|
- | - | |
08 | 2.1224: Replace boiler | $14,158 | $66,000 | - | - |
$14,158
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $139,996 | $206,600 |
$36,682
621,725
kWh
|
$539
-
kW-mo/yr
|
$78,295
-
MMBtu
|
$12,000
-
lb
|
$12,480 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Increase in Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs