Assessment Year | 2022 |
---|---|
Principal Product | Metal Fabrication |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $1 M to 5M |
# of Employees | 10 |
Plant Area |
35,000
ft2
|
Annual Production | 50,000
units
|
Production Hrs. Annual | 2,444
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $80,701 | 812,945 |
kWh
|
$0.099 |
Electricity Demand | $10,668 | 2,784 |
kW-mo/yr
|
$3.83 |
Fuel Oil #2 | $10,000 | 417 |
MMBtu
|
$23.98 |
TOTAL YEARLY COSTS | $101,369 | |||
RECOMMENDED SAVINGS* | $66,456 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $22,237 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $242 | $25 |
$242
2,437
kWh
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,612 | $675 |
$6,612
66,789
kWh
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $199 | $53 |
$164
1,660
kWh
|
$35
-
kW-mo/yr
|
- | - | |
04 | 2.7444: Close holes and openings in building such as broken windows | $121 | $49 |
$121
1,218
kWh
|
- | - | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $482 | $240 |
$482
4,867
kWh
|
- | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $99 | $50 |
$99
999
kWh
|
- | - | - | |
07 | 3.2142: Use tanks with a conical bottom outlet section to reduce waste associated with the interface of two liquids | $1,451 | $1,103 | - | - | - |
$1,451
-
gal
|
|
08 | 2.7232: Replace existing hvac unit with high efficiency model | $15,305 | $31,464 |
$15,305
154,595
kWh
|
- | - | - | |
09 | 2.3212: Optimize plant power factor | $464 | $3,415 | - | - | $464 | - | |
10 | 2.9114: Use solar heat to make electricty | $41,481 | $646,020 |
$41,481
419,000
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $66,456 | $683,094 |
$64,506
651,565
kWh
|
$35
-
kW-mo/yr
|
$464 |
$1,451
-
gal
|
||
TOTAL IMPLEMENTED | $22,237 | $32,241 |
$22,202
224,262
kWh
|
$35
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs