Assessment Year | 2015 |
---|---|
Principal Product | Blown film plastic bags |
NAICS | 326111: Plastics Bag and Pouch Manufacturing |
SIC | 2673: Plastics, Foil, and Coated Paper Bags |
Sales Range | $50 M to 100M |
# of Employees | 141 |
Plant Area |
70,000
ft2
|
Annual Production | 52,389
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $450,209 | 7,648,101 |
kWh
|
$0.059 |
Electricity Demand | $105,321 | 16,524 |
kW-mo/yr
|
$6.37 |
Electricity Fees | $18,294 | - |
|
- |
Natural Gas | $35,404 | 6,818 |
MMBtu
|
$5.19 |
LPG | $7,495 | 365 |
MMBtu
|
$20.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $149,388 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.3311: Replace dc equipment with ac equipment | $109,964 | $421,778 |
$91,031
1,545,523
kWh
|
$18,933
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $22,812 | $4,180 | - | - |
$(-7,168.0)
-
MMBtu
|
$29,980
-
MMBtu
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $12,081 | $30,000 | - | - |
$12,081
-
MMBtu
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $857 | $2,096 |
$709
12,064
kWh
|
$148
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $792 | $450 |
$332
5,635
kWh
|
$197
-
kW-mo/yr
|
- | - | $66 | $197 | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $778 | $1,230 |
$644
10,936
kWh
|
$134
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.3137: Use power during off-peak periods | $539 | $20 | - |
$539
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7135: Install occupancy sensors | $971 | $1,050 |
$656
11,138
kWh
|
$315
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $326 | $275 |
$176
2,996
kWh
|
$26
-
kW-mo/yr
|
- | - | $52 | $72 | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $268 | $119 |
$210
3,564
kWh
|
$58
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $149,388 | $461,198 |
$93,758
1,591,856
kWh
|
$20,350
-
kW-mo/yr
|
$4,913
-
MMBtu
|
$29,980
-
MMBtu
|
$118 | $269 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs