Assessment Year | 2020 |
---|---|
Principal Product | Plastics |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 14 |
Plant Area |
19,000
ft2
|
Annual Production | 5,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $107,569 | 1,128,320 |
kWh
|
$0.095 |
TOTAL YEARLY COSTS | $107,569 | |||
RECOMMENDED SAVINGS* | $24,393 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,072 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $796 | $300 |
$796
8,354
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,970 | $1,800 |
$5,970
62,625
kWh
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,740 | - |
$5,740
60,205
kWh
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $566 | $375 |
$566
5,942
kWh
|
|
05 | 2.7135: Install occupancy sensors | $31 | $45 |
$31
328
kWh
|
|
06 | 2.6231: Utilize controls to operate equipment only when needed | $1,553 | $7,413 |
$1,553
16,286
kWh
|
|
07 | 2.2622: Replace existing chiller with high efficiency model | $9,737 | $81,000 |
$9,737
102,132
kWh
|
|
TOTAL RECOMMENDED | $24,393 | $90,933 |
$24,393
255,872
kWh
|
||
TOTAL IMPLEMENTED | $13,072 | $2,475 |
$13,072
137,126
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs