| Assessment Year | 2020 |
|---|---|
| Principal Product | Plastic Conveyor Components |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 150 |
| Plant Area |
224,790
ft2
|
| Annual Production | 16,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $1,268,638 | 19,468,800 |
kWh
|
$0.065 | |
| Waste Disposal Costs | |||||
| Water Usage | $11,436 | 1,949 |
Tgal
|
$5.87 | |
| TOTAL YEARLY COSTS | $1,280,074 | ||||
| RECOMMENDED SAVINGS* | $261,359 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $2,834 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $2,727 | $300 |
$2,727
41,850
kWh
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,560 | - |
$2,560
39,287
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $114 | $50 |
$114
1,747
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $30,208 | $17,766 |
$30,208
463,577
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $274 | - |
$274
4,204
kWh
|
|
| 06 | 2.2622: Replace existing chiller with high efficiency model | $225,476 | $1,204,486 |
$225,476
3,460,205
kWh
|
|
| TOTAL RECOMMENDED | $261,359 | $1,222,602 |
$261,359
4,010,870
kWh
|
||
| TOTAL IMPLEMENTED | $2,834 | - |
$2,834
43,491
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs