ITAC Assessment: LS1912
ITAC logo
ITAC Assessment: LS1912
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2019
Principal Product Aluminum Extrusion Alloys
NAICS 331318: Other Aluminum Rolling, Drawing, and Extruding
SIC 3354: Aluminum Extruded Products
Sales Range $10
M
to 50
M
# of Employees 206
Plant Area 232,000
ft2
Annual Production 11,000,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $581,892 6,617,244
kWh
Natural Gas $169,984 30,362
MMBtu
Waste Disposal Costs
Water Usage $2,506 761
Tgal
TOTAL YEARLY COSTS $754,382
RECOMMENDED SAVINGS* $1,227,370 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Personnel Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $1,696 $50 $1,696
19,291
kWh
-
02 2.6231: Utilize controls to operate equipment only when needed $4,767 $150 $4,767
54,212
kWh
-
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,179 $630 $11,179
127,125
kWh
-
04 4.441: Install automatic packing equipment $1,164,856 $900,000 $(-5,144.0)
(-58,500)
kWh
$1,170,000
05 2.7142: Utilize higher efficiency lamps and/or ballasts $42,700 $46,200 $42,700
485,578
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $1,657 $2,850 $1,657
18,841
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $515 $1,198 $515
5,854
kWh
-
TOTAL RECOMMENDED $1,227,370 $951,078 $57,370
652,401
kWh
$1,170,000
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs