| Assessment Year | 2019 |
|---|---|
| Principal Product | Wastewater/Sewage Treatment |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4952: Sewerage Systems |
| Sales Range | less than $500 k |
| # of Employees | 15 |
| Plant Area |
4,356,000
ft2
|
| Annual Production | 3,650,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $418,384 | 6,255,200 |
kWh
|
$0.067 |
| Natural Gas | $56,668 | 5,437 |
MMBtu
|
$10.42 |
| TOTAL YEARLY COSTS | $475,052 | |||
| RECOMMENDED SAVINGS* | $71,218 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $651 | $25 |
$651
9,729
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,381 | $174 |
$2,381
35,592
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $1,929 | $325 |
$1,929
28,843
kWh
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,832 | $1,736 |
$6,832
102,142
kWh
|
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $1,758 | $500 |
$1,758
26,280
kWh
|
|
| 06 | 2.4322: Use or replace with energy efficient substitutes | $40,165 | $22,200 |
$40,165
600,498
kWh
|
|
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,502 | $12,000 |
$17,502
261,675
kWh
|
|
| TOTAL RECOMMENDED | $71,218 | $36,960 |
$71,218
1,064,759
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs