Assessment Year 2019
Principal Product Steel Sheet Metal Parts
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3441: Fabricated Structural Metal
Sales Range $5
M
to 10
M
# of Employees 50
Plant Area 40,000
ft2
Annual Production 10,000
ton
Production Hrs. Annual 2,600
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $21,359 184,440
kWh
Natural Gas $20,000 4,000
MMBtu
Fuel Oil #2 $30,000 6,000
MMBtu
Other Energy $30,000 6,000
MMBtu
TOTAL YEARLY COSTS $101,359
RECOMMENDED SAVINGS* $5,764 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $904

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings
01 2.7261: Install timers and/or thermostats $1,781 $100 $1,781
15,356
kWh
-
02 2.8123: Pay utility bills on time $373 - - $373
03 2.4231: Reduce the pressure of compressed air to the minimum required $229 $25 $229
1,977
kWh
-
04 2.7134: Use photocell controls $1,096 $250 $1,096
9,464
kWh
-
05 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $1,710 $495 $1,710
14,759
kWh
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $44 $41 $44
378
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $531 $10,000 $531
4,586
kWh
-
TOTAL RECOMMENDED $5,764 $10,911 $5,391
46,520
kWh
$373
TOTAL IMPLEMENTED $904 $10,000 $531
4,586
kWh
$373
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs