Assessment Year | 2019 |
---|---|
Principal Product | Polypropylene |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $500 k to 1M |
# of Employees | 6 |
Plant Area |
25,000
ft2
|
Annual Production | 780,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $75,942 | 954,072 |
kWh
|
$0.080 | |
Electricity Demand | $61,701 | 4,710 |
kW-mo/yr
|
$13.10 | |
Waste Disposal Costs | |||||
Water Usage | $790 | 425 |
Tgal
|
$1.86 | |
TOTAL YEARLY COSTS | $138,433 | ||||
RECOMMENDED SAVINGS* | $21,755 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $302 | $50 |
$302
3,790
kWh
|
- | |
02 | 2.7124: Make a practice of turning off lights when not needed | $1,921 | $500 |
$1,921
24,018
kWh
|
- | |
03 | 2.6231: Utilize controls to operate equipment only when needed | $180 | $75 |
$180
2,245
kWh
|
- | |
04 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $305 | $180 |
$305
3,827
kWh
|
- | |
05 | 2.6218: Turn off equipment when not in use | $40 | $25 |
$40
504
kWh
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,396 | $6,225 |
$8,396
105,481
kWh
|
- | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $179 | $135 |
$179
2,242
kWh
|
- | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,362 | $10,917 |
$7,038
87,971
kWh
|
$3,324
-
kW-mo/yr
|
|
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $70 | $205 |
$70
885
kWh
|
- | |
TOTAL RECOMMENDED | $21,755 | $18,312 |
$18,431
230,963
kWh
|
$3,324
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs