| Assessment Year | 2019 |
|---|---|
| Principal Product | Ground Coffee |
| NAICS | 311920: Coffee and Tea Manufacturing |
| SIC | 2095: Roasted Coffee |
| Sales Range | $10 M to 50M |
| # of Employees | 10 |
| Plant Area |
20,000
ft2
|
| Annual Production | 1,500,000
lb
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $12,615 | 117,760 |
kWh
|
$0.11 | |
| Electricity Demand | $3,864 | 636 |
kW-mo/yr
|
$6.08 | |
| Natural Gas | $15,522 | 2,062 |
MMBtu
|
$7.53 | |
| LPG | $32,000 | 6,400 |
MMBtu
|
$5.00 | |
| Fuel Oil #2 | $30,000 | 6,000 |
MMBtu
|
$5.00 | |
| Other Energy | $6,000 | 1,200 |
MMBtu
|
$5.00 | |
| Waste Disposal Costs | |||||
| Water Usage | $4,068 | 24 |
Tgal
|
$169.50 | |
| TOTAL YEARLY COSTS | $104,069 | ||||
| RECOMMENDED SAVINGS* | $4,023 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $1,019 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6231: Utilize controls to operate equipment only when needed | $1,079 | $150 |
$1,079
10,083
kWh
|
- | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $135 | - |
$135
1,260
kWh
|
- | - | |
| 03 | 3.7312: Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings | $839 | - |
$839
7,833
kWh
|
- | - | |
| 04 | 2.2136: Install / repair insulation on steam lines | $480 | $240 | - | - |
$480
-
MMBtu
|
|
| 05 | 2.6218: Turn off equipment when not in use | $45 | - |
$45
423
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,445 | $2,189 |
$1,080
10,091
kWh
|
$365
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $4,023 | $2,579 |
$3,178
29,690
kWh
|
$365
-
kW-mo/yr
|
$480
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,019 | - |
$1,019
9,516
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs