Assessment Year | 2018 |
---|---|
Principal Product | Processed meats |
NAICS | 311612: Meat Processed from Carcasses |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $1 M to 5M |
# of Employees | 22 |
Plant Area |
33,000
ft2
|
Annual Production | 13,730,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $72,768 | 850,080 |
kWh
|
$0.086 | |
Electricity Demand | $17,616 | 1,992 |
kW-mo/yr
|
$8.84 | |
Natural Gas | $9,937 | 1,202 |
MMBtu
|
$8.27 | |
Waste Disposal Costs | |||||
Water Usage | $9,167 | 536 |
Tgal
|
$17.09 | |
TOTAL YEARLY COSTS | $109,488 | ||||
RECOMMENDED SAVINGS* | $13,069 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $1,090 | $100 | - |
$1,090
-
kW-mo/yr
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $134 | $45 |
$134
1,560
kWh
|
- | - | |
03 | 2.7135: Install occupancy sensors | $401 | $300 |
$401
4,659
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,902 | $4,019 |
$3,097
36,017
kWh
|
$1,805
-
kW-mo/yr
|
- | |
05 | 2.2511: Insulate bare equipment | $364 | $440 | - | - |
$364
-
MMBtu
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $33 | $50 |
$33
391
kWh
|
- | - | |
07 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $6,145 | $11,000 | - | - |
$6,145
-
MMBtu
|
|
TOTAL RECOMMENDED | $13,069 | $15,954 |
$3,665
42,627
kWh
|
$2,895
-
kW-mo/yr
|
$6,509
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs