Assessment Year | 2022 |
---|---|
Principal Product | Offices |
NAICS | 541330: Engineering Services |
SIC | 8748: Business Consulting Services, Not Elsewhere Classified |
Sales Range | less than $500 k |
# of Employees | 10 |
Plant Area |
47,797
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,852 | 113,969 |
kWh
|
$0.12 |
Natural Gas | $3,021 | 208 |
MMBtu
|
$14.52 |
TOTAL YEARLY COSTS | $16,873 | |||
RECOMMENDED SAVINGS* | $12,910 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,646 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $3,718 | $350 |
$3,718
30,472
kWh
|
- | |
02 | 2.1321: Replace fossil fuel equipment with electrical equipment | $3,014 | $1,496 | - |
$3,014
-
MMBtu
|
|
03 | 2.7135: Install occupancy sensors | $250 | $200 |
$250
2,060
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,928 | $6,120 |
$5,928
48,594
kWh
|
- | |
TOTAL RECOMMENDED | $12,910 | $8,166 |
$9,896
81,126
kWh
|
$3,014
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,646 | $6,470 |
$9,646
79,066
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs