Assessment Year 2023
Principal Product Theater
NAICS 711110: Theater Companies and Dinner Theaters
SIC 7922: Theatrical Producers (Except Motion Picture) and Miscellaneous Theatrical Services
Sales Range less than $500
k
# of Employees 8
Plant Area 22,600
ft2
Annual Production 1
units
Production Hrs. Annual 1,820
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $61,277 664,100
kWh
Electricity Demand $7,470 1,816
kW-mo/yr
TOTAL YEARLY COSTS $68,747
RECOMMENDED SAVINGS* $24,179 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,667

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.2625: Chill water to the highest temperature possible $803 - $803
8,723
kWh
-
02 2.7261: Install timers and/or thermostats $14,390 $1,190 $14,390
156,408
kWh
-
03 2.7135: Install occupancy sensors $346 $100 $346
3,757
kWh
-
04 2.7423: Reduce heat gain by window tinting $2,512 $1,050 $2,512
27,300
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $6,128 $17,331 $4,766
51,799
kWh
$1,362
-
kW-mo/yr
TOTAL RECOMMENDED $24,179 $19,671 $22,817
247,987
kWh
$1,362
-
kW-mo/yr
TOTAL IMPLEMENTED $21,667 $18,621 $20,305
220,687
kWh
$1,362
-
kW-mo/yr
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs