| Assessment Year | 2023 |
|---|---|
| Principal Product | Theater |
| NAICS | 711110: Theater Companies and Dinner Theaters |
| SIC | 7922: Theatrical Producers (Except Motion Picture) and Miscellaneous Theatrical Services |
| Sales Range | less than $500 k |
| # of Employees | 8 |
| Plant Area |
22,600
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 1,820
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $61,277 | 664,100 |
kWh
|
$0.092 |
| Electricity Demand | $7,470 | 1,816 |
kW-mo/yr
|
$4.11 |
| TOTAL YEARLY COSTS | $68,747 | |||
| RECOMMENDED SAVINGS* | $24,179 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,667 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2625: Chill water to the highest temperature possible | $803 | - |
$803
8,723
kWh
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $14,390 | $1,190 |
$14,390
156,408
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $346 | $100 |
$346
3,757
kWh
|
- | |
| 04 | 2.7423: Reduce heat gain by window tinting | $2,512 | $1,050 |
$2,512
27,300
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,128 | $17,331 |
$4,766
51,799
kWh
|
$1,362
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $24,179 | $19,671 |
$22,817
247,987
kWh
|
$1,362
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $21,667 | $18,621 |
$20,305
220,687
kWh
|
$1,362
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs