| Assessment Year | 2022 |
|---|---|
| Principal Product | Aircraft hangar rental and terminal |
| NAICS | 488119: Other Airport Operations |
| SIC | 4581: Airports, Flying Fields, and Airport Terminal Services |
| Sales Range | less than $500 k |
| # of Employees | 3 |
| Plant Area |
100,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 3,650
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $14,532 | 118,604 |
kWh
|
$0.12 |
| Electricity Demand | $1,388 | 455 |
kW-mo/yr
|
$3.05 |
| TOTAL YEARLY COSTS | $15,920 | |||
| RECOMMENDED SAVINGS* | $5,555 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,430 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $1,249 | $38 |
$1,249
10,192
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $57 | $25 |
$57
467
kWh
|
- | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $125 | $80 |
$125
1,017
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,124 | $3,917 |
$3,708
30,262
kWh
|
$416
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $5,555 | $4,060 |
$5,139
41,938
kWh
|
$416
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $5,430 | $3,980 |
$5,014
40,921
kWh
|
$416
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs