| Assessment Year | 2022 |
|---|---|
| Principal Product | Elementary School |
| NAICS | 611110: Elementary and Secondary Schools |
| SIC | 8211: Elementary and Secondary Schools |
| Sales Range | less than $500 k |
| # of Employees | 30 |
| Plant Area |
40,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $51,479 | 570,800 |
kWh
|
$0.090 |
| Electricity Demand | $10,803 | 2,622 |
kW-mo/yr
|
$4.12 |
| TOTAL YEARLY COSTS | $62,282 | |||
| RECOMMENDED SAVINGS* | $8,309 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,925 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $968 | $150 |
$968
10,752
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $444 | $250 |
$444
4,927
kWh
|
- | |
| 03 | 2.2222: Convert liquid heaters from underfiring to immersion or submersion heating | $3,384 | $2,100 |
$3,384
37,592
kWh
|
- | |
| 04 | 2.7442: Keep doors and windows shut when not on use | $159 | $150 |
$159
1,758
kWh
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,354 | $8,296 |
$2,666
29,624
kWh
|
$688
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $8,309 | $10,946 |
$7,621
84,653
kWh
|
$688
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $4,925 | $8,846 |
$4,237
47,061
kWh
|
$688
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs