| Assessment Year | 2024 |
|---|---|
| Principal Product | Industrial Laundry Service |
| NAICS | 812332: Industrial Launderers |
| SIC | 7218: Industrial Launderers |
| Sales Range | $10 M to 50M |
| # of Employees | 185 |
| Plant Area |
168,000
ft2
|
| Annual Production | 17,160,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $126,561 | 1,461,888 |
kWh
|
$0.087 |
| Electricity Demand | $14,787 | 3,589 |
kW-mo/yr
|
$4.12 |
| Natural Gas | $106,431 | 12,472 |
MMBtu
|
$8.53 |
| TOTAL YEARLY COSTS | $247,779 | |||
| RECOMMENDED SAVINGS* | $248,542 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $180,540 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,796 | $25 |
$1,796
20,640
kWh
|
- | - | - | |
| 02 | 2.7261: Install timers and/or thermostats | $1,962 | $75 |
$1,962
22,549
kWh
|
- | - | - | |
| 03 | 2.2437: Recover waste heat from equipment | $17,495 | $20,000 | - | - |
$17,495
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,104 | $1,413 |
$1,013
11,644
kWh
|
$91
-
kW-mo/yr
|
- | - | |
| 05 | 4.111: Add equipment/ operators to reduce production bottleneck | $175,678 | $600,000 |
$(-18,419.0)
(-211,719)
kWh
|
- | - | $194,097 | |
| 06 | 2.7232: Replace existing hvac unit with high efficiency model | $12,486 | $113,400 |
$12,486
143,520
kWh
|
- | - | - | |
| 07 | 2.9114: Use solar heat to make electricty | $38,021 | $514,800 |
$38,021
437,019
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $248,542 | $1,249,713 |
$36,859
423,653
kWh
|
$91
-
kW-mo/yr
|
$17,495
-
MMBtu
|
$194,097 | ||
| TOTAL IMPLEMENTED | $180,540 | $601,513 |
$(-13,648.0)
(-156,886)
kWh
|
$91
-
kW-mo/yr
|
- | $194,097 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs