| Assessment Year | 2017 |
|---|---|
| Principal Product | Paper Cups |
| NAICS | 322219: Other Paperboard Container Manufacturing |
| SIC | 2656: Sanitary Food Containers, Except Folding |
| Sales Range | $5 M to 10M |
| # of Employees | 40 |
| Plant Area |
23,000
ft2
|
| Annual Production | 110,000
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $187,013 | 2,807,040 |
kWh
|
$0.067 |
| Electricity Demand | $81,417 | 10,856 |
kW-mo/yr
|
$7.50 |
| Other Gas | $4,630 | 135 |
MMBtu
|
$34.30 |
| TOTAL YEARLY COSTS | $273,060 | |||
| RECOMMENDED SAVINGS* | $18,230 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $7,009 | $200 |
$7,009
105,210
kWh
|
- | |
| 02 | 2.7134: Use photocell controls | $8,468 | $4,570 |
$7,042
105,706
kWh
|
$1,426
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,305 | $2,200 |
$2,305
34,594
kWh
|
- | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $135 | $290 |
$135
2,024
kWh
|
- | |
| 05 | 2.7425: Clean or color roof to reduce solar load | $313 | $1,105 |
$313
4,698
kWh
|
- | |
| TOTAL RECOMMENDED | $18,230 | $8,365 |
$16,804
252,232
kWh
|
$1,426
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs