Assessment Year | 2004 |
---|---|
Principal Product | food |
NAICS | 311821: Cookie and Cracker Manufacturing |
SIC | 2052: Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 210 |
Plant Area |
250,000
ft2
|
Annual Production | 30,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $280,767 | 3,461,654 |
kWh
|
$0.081 |
Electricity Demand | $119,899 | 8,676 |
kW-mo/yr
|
$13.82 |
Electricity Fees | $6,068 | - |
|
- |
Natural Gas | $193,816 | 26,821 |
MMBtu
|
$7.23 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,042 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,042 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $238 | $200 |
$204
2,344
kWh
|
$34
-
kW-mo/yr
|
- | |
02 | 2.4239: Eliminate or reduce compressed air usage | $386 | $735 |
$330
3,800
kWh
|
$56
-
kW-mo/yr
|
- | |
03 | 2.4225: Install common header on compressors | $1,631 | - |
$1,394
16,051
kWh
|
$237
-
kW-mo/yr
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,787 | $13,324 |
$5,633
64,877
kWh
|
$1,154
-
kW-mo/yr
|
- | |
05 | 4.322: Eliminate old stock and modify inventory control | $75,000 | $8,800 | - | - | $75,000 | |
TOTAL RECOMMENDED | $84,042 | $23,059 |
$7,561
87,072
kWh
|
$1,481
-
kW-mo/yr
|
$75,000 | ||
TOTAL IMPLEMENTED | $9,042 | $14,259 |
$7,561
87,072
kWh
|
$1,481
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs