Assessment Year | 2002 |
---|---|
Principal Product | television plastic cabinets |
NAICS |
n/a
|
SIC | 2519: Household Furniture, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
84,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 1,952
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,230 | 894,660 |
kWh
|
$0.100 |
Electricity Demand | $29,770 | 3,564 |
kW-mo/yr
|
$8.35 |
Electricity Fees | $5,618 | - |
|
- |
Natural Gas | $43,928 | 6,884 |
MMBtu
|
$6.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $81,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,690 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $337 | $250 |
$853
6,802
kWh
|
$264
-
kW-mo/yr
|
$(-780.0) | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $1,001 | $200 |
$766
6,106
kWh
|
$235
-
kW-mo/yr
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $13,662 | $1,100 |
$10,442
83,468
kWh
|
$3,220
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,190 | $90 |
$1,821
14,523
kWh
|
$369
-
kW-mo/yr
|
- | - | |
05 | 2.7131: Add area lighting switches | $898 | $800 |
$687
5,481
kWh
|
$211
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,602 | $60 |
$1,348
10,277
kWh
|
$254
-
kW-mo/yr
|
- | - | |
07 | 4.425: Eliminate/reduce redundant inspections | $39,000 | $20,250 | - | - | $39,000 | - | |
08 | 4.322: Eliminate old stock and modify inventory control | $22,500 | $1,000 | - | - | - | $22,500 | |
TOTAL RECOMMENDED | $81,190 | $23,750 |
$15,917
126,657
kWh
|
$4,553
-
kW-mo/yr
|
$38,220 | $22,500 | ||
TOTAL IMPLEMENTED | $19,690 | $2,500 |
$15,917
126,657
kWh
|
$4,553
-
kW-mo/yr
|
$(-780.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs