| Assessment Year | 2008 |
|---|---|
| Principal Product | Rice |
| NAICS | 311212: Rice Milling |
| SIC | 2044: Rice Milling |
| Sales Range | $50 M to 100M |
| # of Employees | 50 |
| Plant Area |
300,000
ft2
|
| Annual Production | 700,000,000
lb
|
| Production Hrs. Annual | 6,552
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $586,498 | 7,787,545 |
kWh
|
$0.075 |
| Electricity Demand | $94,306 | 22,890 |
kW-mo/yr
|
$4.12 |
| Electricity Fees | $24,031 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $105,779 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,281 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $95,128 | $96,000 |
$91,911
1,220,436
kWh
|
- | $3,217 | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $3,831 | $1,500 |
$3,701
49,140
kWh
|
- | $130 | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,016 | $760 |
$2,914
38,687
kWh
|
- | $102 | - | |
| 04 | 2.7134: Use photocell controls | $2,258 | $210 |
$2,182
28,969
kWh
|
- | $76 | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $586 | $350 |
$251
3,329
kWh
|
$21
-
kW-mo/yr
|
$10 | $304 | |
| 06 | 2.7135: Install occupancy sensors | $422 | $180 |
$408
5,411
kWh
|
- | $14 | - | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $273 | $319 |
$264
3,504
kWh
|
- | $9 | - | |
| 08 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $265 | $152 |
$256
3,395
kWh
|
- | $9 | - | |
| TOTAL RECOMMENDED | $105,779 | $99,471 |
$101,887
1,352,871
kWh
|
$21
-
kW-mo/yr
|
$3,567 | $304 | ||
| TOTAL IMPLEMENTED | $3,281 | $912 |
$3,170
42,082
kWh
|
- | $111 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs