ITAC Assessment: LL0278
ITAC logo
ITAC Assessment: LL0278
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2007
Principal Product Rope
NAICS 314994: Rope, Cordage, Twine, Tire Cord, and Tire Fabric Mills
SIC 2298: Cordage and Twine
Sales Range $5
M
to 10
M
# of Employees 100
Plant Area 78,000
ft2
Annual Production 5,000,000
lb
Production Hrs. Annual 6,000
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $304,951 3,657,365
kWh
Natural Gas $94,323 9,432
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $73,044 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $56,442

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $29,656 $10,860 $30,232
362,583
kWh
- - $(-576.0) - -
02 2.7224: Reduce space conditioning during non-working hours $14,779 $1,384 $14,779
177,249
kWh
- - - - -
03 4.611: Begin a practice of predictive / preventative maintenance $9,981 $150 $8,481
101,712
kWh
- - - - $1,500
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $8,854 $2,400 $8,854
106,186
kWh
- - - - -
05 2.4222: Install adequate dryers on air lines to eliminate blowdown $2,388 $542 $2,388
28,645
kWh
- - - - -
06 4.611: Begin a practice of predictive / preventative maintenance $1,920 $1,147 - - - - $1,920 -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,744 $1,050 $833
9,986
kWh
- $911 - - -
08 2.2511: Insulate bare equipment $1,696 $912 $1,696
20,340
kWh
- - - - -
09 2.2511: Insulate bare equipment $1,240 $428 - $1,240
-
MMBtu
- - - -
10 2.6211: Conserve energy by efficient use of vending machines $583 $668 $583
6,989
kWh
- - - - -
11 2.7111: Reduce illumination to minimum necessary levels $203 $120 $203
2,440
kWh
- - - - -
TOTAL RECOMMENDED $73,044 $19,661 $68,049
816,130
kWh
$1,240
-
MMBtu
$911 $(-576.0) $1,920 $1,500
TOTAL IMPLEMENTED $56,442 $17,181 $52,687
631,892
kWh
- $911 $(-576.0) $1,920 $1,500
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings Ancillary Material Cost Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs