Assessment Year | 2007 |
---|---|
Principal Product | Glassware |
NAICS | 327212: Other Pressed and Blown Glass and Glassware Manufacturing |
SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 1,000 |
Plant Area |
500,000
ft2
|
Annual Production | 200,000,000
pieces
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,639,601 | 62,355,601 |
kWh
|
$0.026 |
Electricity Demand | $983,336 | 96,118 |
kW-mo/yr
|
$10.23 |
Electricity Fees | $86,557 | - |
|
- |
Natural Gas | $10,169,864 | 1,457,087 |
MMBtu
|
$6.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $184,290 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $58,782 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $102,410 | $49,360 |
$63,718
2,423,646
kWh
|
$35,420
-
kW-mo/yr
|
$3,272 | - | - | |
02 | 2.2511: Insulate bare equipment | $58,782 | $19,636 | - | - | - |
$58,782
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,485 | $7,000 |
$1,678
63,840
kWh
|
$897
-
kW-mo/yr
|
$87 | - | $5,823 | |
04 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $7,489 | $422 |
$4,660
177,254
kWh
|
$2,590
-
kW-mo/yr
|
$239 | - | - | |
05 | 2.7145: Install skylights | $2,828 | $5,040 |
$2,738
104,160
kWh
|
- | $90 | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $1,024 | $1,499 |
$991
37,701
kWh
|
- | $33 | - | - | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $832 | $830 |
$263
10,006
kWh
|
$542
-
kW-mo/yr
|
$27 | - | - | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $1,020 | $2,338 |
$643
24,461
kWh
|
$344
-
kW-mo/yr
|
$33 | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $903 | $1,169 |
$562
21,363
kWh
|
$312
-
kW-mo/yr
|
$29 | - | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $517 | $5,436 |
$499
18,994
kWh
|
- | $18 | - | - | |
TOTAL RECOMMENDED | $184,290 | $92,730 |
$75,752
2,881,425
kWh
|
$40,105
-
kW-mo/yr
|
$3,828 |
$58,782
-
MMBtu
|
$5,823 | ||
TOTAL IMPLEMENTED | $58,782 | $19,636 | - | - | - |
$58,782
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs