Assessment Year | 2006 |
---|---|
Principal Product | Aggregate |
NAICS | 327110: Pottery, Ceramics, and Plumbing Fixture Manufacturing |
SIC | 3295: Minerals and Earths, Ground or Otherwise Treated |
Sales Range | $10 M to 50M |
# of Employees | 42 |
Plant Area |
215,000
ft2
|
Annual Production | 500,000
units
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $880,405 | 9,400,800 |
kWh
|
$0.094 |
Electricity Fees | $15,518 | - |
|
- |
Natural Gas | $107,699 | 9,602 |
MMBtu
|
$11.22 |
Coal | $2,538,194 | 680,660 |
MMBtu
|
$3.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,159,616 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,151,055 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Coal Savings |
---|---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $818,045 | $90,421 | - | - |
$818,045
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $243,412 | $19,445 | - | - |
$243,412
-
MMBtu
|
|
03 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $53,421 | $607 |
$52,497
560,561
kWh
|
$924 | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $22,045 | $3,640 |
$21,664
231,330
kWh
|
$381 | - | |
05 | 2.7134: Use photocell controls | $12,108 | $780 |
$11,898
127,052
kWh
|
$210 | - | |
06 | 2.7132: Install timers on light switches in little used areas | $6,327 | $450 |
$6,218
66,394
kWh
|
$109 | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,490 | $30 |
$1,464
15,632
kWh
|
$26 | - | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $965 | $240 |
$948
10,118
kWh
|
$17 | - | |
09 | 2.6211: Conserve energy by efficient use of vending machines | $667 | $623 |
$655
6,989
kWh
|
$12 | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $602 | $1,379 |
$591
6,311
kWh
|
$11 | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $534 | $388 |
$525
5,604
kWh
|
$9 | - | |
TOTAL RECOMMENDED | $1,159,616 | $118,003 |
$96,460
1,029,991
kWh
|
$1,699 |
$1,061,457
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,151,055 | $115,311 |
$88,048
940,179
kWh
|
$1,550 |
$1,061,457
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Coal Savings |