Assessment Year | 2005 |
---|---|
Principal Product | Rice Milling |
NAICS | 311212: Rice Milling |
SIC | 2044: Rice Milling |
Sales Range | $100 M to 500M |
# of Employees | 400 |
Plant Area |
375,000
ft2
|
Annual Production | 90,000,000
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,109,668 | 57,613,300 |
kWh
|
$0.019 |
Electricity Demand | $1,000,000 | 121,906 |
kW-mo/yr
|
$8.20 |
Electricity Fees | $97,765 | - |
|
- |
Natural Gas | $557,163 | 421,009 |
MMBtu
|
$1.32 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $323,462 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $150,491 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $91,143 | - |
$88,791
4,610,100
kWh
|
- | $3,552 | - |
$(-1,200.0)
-
MMBtu
|
- | |
02 | 2.2511: Insulate bare equipment | $70,461 | - | - | - | - |
$70,461
-
MMBtu
|
- | - | |
03 | 2.2442: Preheat combustion air with waste heat | $44,802 | $20,000 | - | - | - |
$44,802
-
MMBtu
|
- | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $43,777 | $6,100 |
$24,586
1,276,524
kWh
|
$17,507
-
kW-mo/yr
|
$1,684 | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $35,683 | $27,760 |
$34,311
1,781,471
kWh
|
- | $1,372 | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $10,014 | - |
$9,629
499,924
kWh
|
- | $385 | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,717 | $2,000 |
$5,290
274,671
kWh
|
$4,053
-
kW-mo/yr
|
$374 | - | - | - | |
08 | 2.7229: Air condition only space necessary | $5,876 | $60 | - | - | - |
$5,876
-
MMBtu
|
- | - | |
09 | 2.7134: Use photocell controls | $2,101 | $700 |
$2,020
104,878
kWh
|
- | $81 | - | - | - | |
10 | 2.7224: Reduce space conditioning during non-working hours | $756 | - |
$727
37,724
kWh
|
- | $29 | - | - | - | |
11 | 2.7135: Install occupancy sensors | $597 | - |
$574
29,806
kWh
|
- | $23 | - | - | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,185 | $1,120 |
$205
10,652
kWh
|
- | $8 | - | - | $972 | |
13 | 4.611: Begin a practice of predictive / preventative maintenance | $7,350 | $3,010 | - | - | - | - | - | $7,350 | |
TOTAL RECOMMENDED | $323,462 | $60,750 |
$166,133
8,625,750
kWh
|
$21,560
-
kW-mo/yr
|
$7,508 |
$121,139
-
MMBtu
|
$(-1,200.0)
-
MMBtu
|
$8,322 | ||
TOTAL IMPLEMENTED | $150,491 | $60,750 |
$66,412
3,448,196
kWh
|
$21,560
-
kW-mo/yr
|
$3,519 |
$50,678
-
MMBtu
|
- | $8,322 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | LPG Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs