| Assessment Year | 2004 |
|---|---|
| Principal Product | Plastic agricultural film |
| NAICS | 326113: Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
| SIC | 3081: Unsupported Plastics Film and Sheet |
| Sales Range | $10 M to 50M |
| # of Employees | 25 |
| Plant Area |
150,000
ft2
|
| Annual Production | 50,000,000
lb
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $761,772 | 17,523,200 |
kWh
|
$0.043 |
| Electricity Demand | $207,104 | 28,260 |
kW-mo/yr
|
$7.33 |
| Electricity Fees | $118,780 | - |
|
- |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,082 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,894 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $10,188 | $1,430 |
$9,072
208,845
kWh
|
- | $1,116 | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $8,957 | $570 |
$6,449
148,466
kWh
|
$1,527
-
kW-mo/yr
|
$981 | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,000 | $2,360 |
$5,343
122,996
kWh
|
- | $657 | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,025 | $770 |
$318
7,323
kWh
|
- | $39 | $668 | |
| 05 | 2.7134: Use photocell controls | $729 | $60 |
$649
14,942
kWh
|
- | $80 | - | |
| 06 | 2.7134: Use photocell controls | $419 | $180 |
$373
8,592
kWh
|
- | $46 | - | |
| 07 | 4.611: Begin a practice of predictive / preventative maintenance | $764 | $158 | - | - | - | $764 | |
| TOTAL RECOMMENDED | $28,082 | $5,528 |
$22,204
511,164
kWh
|
$1,527
-
kW-mo/yr
|
$2,919 | $1,432 | ||
| TOTAL IMPLEMENTED | $17,894 | $4,098 |
$13,132
302,319
kWh
|
$1,527
-
kW-mo/yr
|
$1,803 | $1,432 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs