| Assessment Year | 2003 |
|---|---|
| Principal Product | Oil field equipment |
| NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
28,720
ft2
|
| Annual Production | 9,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $21,226 | 344,401 |
kWh
|
$0.062 |
| Electricity Demand | $945 | 236 |
kW-mo/yr
|
$4.00 |
| Electricity Fees | $887 | - |
|
- |
| Natural Gas | $4,297 | 441 |
MMBtu
|
$9.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,678 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,514 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $6,194 | $328 |
$5,956
96,271
kWh
|
- | $238 | - | - | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $1,952 | $2,121 | - | - | - |
$1,952
-
MMBtu
|
- | |
| 03 | 2.7224: Reduce space conditioning during non-working hours | $1,921 | $192 |
$1,847
29,848
kWh
|
- | $74 | - | - | |
| 04 | 2.6231: Utilize controls to operate equipment only when needed | $1,034 | $763 | - | - | - |
$1,034
-
MMBtu
|
- | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $641 | $20 | - |
$609
-
kW-mo/yr
|
$32 | - | - | |
| 06 | 2.7135: Install occupancy sensors | $534 | $520 |
$513
8,298
kWh
|
- | $21 | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $402 | $210 |
$144
2,330
kWh
|
$12
-
kW-mo/yr
|
$6 | - | $240 | |
| TOTAL RECOMMENDED | $12,678 | $4,154 |
$8,460
136,747
kWh
|
$621
-
kW-mo/yr
|
$371 |
$2,986
-
MMBtu
|
$240 | ||
| TOTAL IMPLEMENTED | $4,514 | $2,333 |
$1,847
29,848
kWh
|
$609
-
kW-mo/yr
|
$106 |
$1,952
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs