ITAC Assessment: LL0161
ITAC logo
ITAC Assessment: LL0161
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2003
Principal Product Oil field equipment
NAICS 333132: Oil and Gas Field Machinery and Equipment Manufacturing
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range $5
M
to 10
M
# of Employees 80
Plant Area 28,720
ft2
Annual Production 9,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Louisiana

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $21,226 344,401
kWh
Electricity Demand $945 236
kW-mo/yr
Electricity Fees $887 -
Natural Gas $4,297 441
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $12,678 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $4,514

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings By-product Production Savings
01 2.7134: Use photocell controls $6,194 $328 $5,956
96,271
kWh
- $238 - -
02 2.7232: Replace existing hvac unit with high efficiency model $1,952 $2,121 - - - $1,952
-
MMBtu
-
03 2.7224: Reduce space conditioning during non-working hours $1,921 $192 $1,847
29,848
kWh
- $74 - -
04 2.6231: Utilize controls to operate equipment only when needed $1,034 $763 - - - $1,034
-
MMBtu
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $641 $20 - $609
-
kW-mo/yr
$32 - -
06 2.7135: Install occupancy sensors $534 $520 $513
8,298
kWh
- $21 - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $402 $210 $144
2,330
kWh
$12
-
kW-mo/yr
$6 - $240
TOTAL RECOMMENDED $12,678 $4,154 $8,460
136,747
kWh
$621
-
kW-mo/yr
$371 $2,986
-
MMBtu
$240
TOTAL IMPLEMENTED $4,514 $2,333 $1,847
29,848
kWh
$609
-
kW-mo/yr
$106 $1,952
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings By-product Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs