Assessment Year | 2001 |
---|---|
Principal Product | Corrugated and solid fiber boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $50 M to 100M |
# of Employees | 140 |
Plant Area |
194,230
ft2
|
Annual Production | 100,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $464,715 | 8,065,600 |
kWh
|
$0.058 |
Electricity Demand | $80,720 | 16,144 |
kW-mo/yr
|
$5.00 |
Electricity Fees | $15,847 | - |
|
- |
Natural Gas | $294,416 | 67,589 |
MMBtu
|
$4.36 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,243 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $44,200 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $4,924 | $7,874 |
$4,924
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.1116: Improve combustion control capability | $33,119 | $18,760 | - | - |
$33,119
-
MMBtu
|
- | - | |
03 | 2.8114: Change rate schedules or other changes in utility service | $16,897 | - | - | $16,897 | - | - | - | |
04 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,407 | - | - | - | - | - |
$1,407
-
lb
|
|
05 | 3.5131: Recycle white water | $25,896 | $175,000 | - | - | - |
$25,896
-
gal
|
- | |
TOTAL RECOMMENDED | $82,243 | $201,634 |
$4,924
-
kW-mo/yr
|
$16,897 |
$33,119
-
MMBtu
|
$25,896
-
gal
|
$1,407
-
lb
|
||
TOTAL IMPLEMENTED | $44,200 | $175,000 | - | $16,897 | - |
$25,896
-
gal
|
$1,407
-
lb
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs