| Assessment Year | 2026 |
|---|---|
| Principal Product | Animal feeds |
| NAICS | 311119: Other Animal Food Manufacturing |
| SIC | 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats |
| Sales Range | $100 M to 500M |
| # of Employees | 96 |
| Plant Area |
100,000
ft2
|
| Annual Production | 125,000
ton
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $311,184 | 3,896,697 |
kWh
|
$0.080 |
| Electricity Demand | $43,776 | 10,840 |
kW-mo/yr
|
$4.04 |
| Electricity Fees | $79,743 | - |
|
- |
| Natural Gas | $118,798 | 25,844 |
MMBtu
|
$4.60 |
| TOTAL YEARLY COSTS | $553,501 | |||
| RECOMMENDED SAVINGS* | $2,090,273 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,048 | - |
$1,915
23,937
kWh
|
$133
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.4226: Use / purchase optimum sized compressor | $138,699 | $35,000 | - | - | - | - | - | $138,699 | |
| 03 | 4.514: Re-arrange equipment layout to reduce handling costs | $1,005,000 | $300,000 | - | - | - | - | - | $1,005,000 | |
| 04 | 2.4321: Upgrade obsolete equipment | $833,198 | $400,000 |
$(-1,040.0)
(-13,000)
kWh
|
$(-242.0)
-
kW-mo/yr
|
- | - | $834,480 | - | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $24,953 | $13,000 |
$20,442
255,528
kWh
|
$4,511
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.2113: Repair or replace steam traps | $3,892 | $4,700 | - | - | - |
$3,892
-
MMBtu
|
- | - | |
| 07 | 2.2442: Preheat combustion air with waste heat | $4,764 | $10,000 |
$(-872.0)
(-9,776)
kWh
|
$(-109.0)
-
kW-mo/yr
|
- |
$5,745
-
MMBtu
|
- | - | |
| 08 | 2.9112: Use solar heat to heat water | $77,719 | $482,154 |
$59,425
742,815
kWh
|
$486
-
kW-mo/yr
|
$17,808 | - | - | - | |
| TOTAL RECOMMENDED | $2,090,273 | $1,244,854 |
$79,870
999,504
kWh
|
$4,779
-
kW-mo/yr
|
$17,808 |
$9,637
-
MMBtu
|
$834,480 | $1,143,699 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs