ITAC Assessment: LE0592
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Deli Items
NAICS 311612: Meat Processed from Carcasses
SIC 2013: Sausages and Other Prepared Meat Products
Sales Range $50
M
to 100
M
# of Employees 95
Plant Area 55,000
ft2
Annual Production 16,000,000
lb
Production Hrs. Annual 3,120
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $408,450 4,084,499
kWh
Electricity Demand $143,062 16,831
kW-mo/yr
Electricity Fees $2,604 -
Natural Gas $284,760 61,016
MMBtu
TOTAL YEARLY COSTS $838,876
RECOMMENDED SAVINGS* $120,609 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $6,457 $100 $4,867
48,672
kWh
$1,590
-
kW-mo/yr
- -
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $40,366 $3,000 $33,634
336,336
kWh
$6,732
-
kW-mo/yr
- -
03 2.4231: Reduce the pressure of compressed air to the minimum required $6,485 $7,000 $6,485
65,848
kWh
- - -
04 2.2622: Replace existing chiller with high efficiency model $2,361 $3,915 $2,114
21,137
kWh
$247
-
kW-mo/yr
- -
05 2.4221: Install compressor air intakes in coolest locations $2,195 $4,000 $1,872
18,720
kWh
$323
-
kW-mo/yr
- -
06 2.4222: Install adequate dryers on air lines to eliminate blowdown $12,213 $24,000 $9,204
92,040
kWh
$3,009
-
kW-mo/yr
- -
07 2.9114: Use solar heat to make electricty $43,842 $126,000 $23,561
235,611
kWh
$306
-
kW-mo/yr
- $19,975
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,177 $26,000 $4,655
46,550
kWh
$1,522
-
kW-mo/yr
- -
09 2.2442: Preheat combustion air with waste heat $513 $2,500 $(-326.0)
(-3,259)
kWh
$(-76.0)
-
kW-mo/yr
$915
-
MMBtu
-
TOTAL RECOMMENDED $120,609 $196,515 $86,066
861,655
kWh
$13,653
-
kW-mo/yr
$915
-
MMBtu
$19,975
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs