Assessment Year | 2025 |
---|---|
Principal Product | EV Stations |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
60,000
ft2
|
Annual Production | 200
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,950 | 447,601 |
kWh
|
$0.12 |
Electricity Demand | $13,549 | 1,568 |
kW-mo/yr
|
$8.64 |
Electricity Fees | $3,520 | - |
|
- |
Natural Gas | $26,446 | 25,527 |
MMBtu
|
$1.04 |
TOTAL YEARLY COSTS | $99,465 | |||
RECOMMENDED SAVINGS* | $79,061 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,438 | - |
$2,153
17,222
kWh
|
$285
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,795 | $1,400 |
$9,528
76,225
kWh
|
$1,267
-
kW-mo/yr
|
- | |
03 | 2.9114: Use solar heat to make electricty | $58,495 | $104,135 |
$58,495
178,698
kWh
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $667 | $2,000 |
$624
4,992
kWh
|
$43
-
kW-mo/yr
|
- | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $1,851 | $6,801 |
$1,747
13,978
kWh
|
$104
-
kW-mo/yr
|
- | |
06 | 2.2442: Preheat combustion air with waste heat | $4,080 | $15,000 |
$(-970.0)
(-7,758)
kWh
|
$(-389.0)
-
kW-mo/yr
|
$5,439
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $735 | $2,997 |
$588
4,705
kWh
|
$147
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $79,061 | $132,333 |
$72,165
288,062
kWh
|
$1,457
-
kW-mo/yr
|
$5,439
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs