Assessment Year 2024
Principal Product Chemical mixing
NAICS 424690: Other Chemical and Allied Products Merchant Wholesalers
SIC 5169: Chemicals and Allied Products, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 238
Plant Area 270,000
ft2
Annual Production 88,504
ton
Production Hrs. Annual 3,822
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $109,916 1,903,767
kWh
Electricity Demand $20,701 4,044
kW-mo/yr
Electricity Fees $28,181 -
Natural Gas $74,821 13,851
MMBtu
TOTAL YEARLY COSTS $233,619
RECOMMENDED SAVINGS* $205,517 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
01 2.7261: Install timers and/or thermostats $27,784 - $784
13,529
kWh
- $27,000
-
MMBtu
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $17,317 $2,200 $14,842
255,896
kWh
$2,475
-
kW-mo/yr
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,395 $660 $1,194
20,592
kWh
$201
-
kW-mo/yr
- - -
04 2.2122: Install / repair insulation on condensate lines $11,387 $25,000 - - $6,005
-
MMBtu
$5,382
-
Tgal
-
05 2.4239: Eliminate or reduce compressed air usage $11,641 $25,639 $11,229
193,610
kWh
$412
-
kW-mo/yr
- - -
06 2.9112: Use solar heat to heat water $132,239 $658,000 $48,474
598,450
kWh
- - - $83,765
07 2.7232: Replace existing hvac unit with high efficiency model $3,754 $33,002 $3,468
59,976
kWh
$286
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $205,517 $744,501 $79,991
1,142,053
kWh
$3,374
-
kW-mo/yr
$33,005
-
MMBtu
$5,382
-
Tgal
$83,765
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs