Assessment Year 2024
Principal Product Light weight furniture
NAICS 337121: Upholstered Household Furniture Manufacturing
SIC 2514: Metal Household Furniture
Sales Range $10
M
to 50
M
# of Employees 38
Plant Area 135,000
ft2
Annual Production 20,000
units
Production Hrs. Annual 2,730
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $75,081 1,005,533
kWh
Electricity Demand $19,467 3,813
kW-mo/yr
Electricity Fees $9,007 -
Natural Gas $83,373 7,618
MMBtu
Waste Disposal Costs
Water Usage $20,379 3
Tgal
TOTAL YEARLY COSTS $207,307
RECOMMENDED SAVINGS* $53,176 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $42,713

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
01 2.8114: Change rate schedules or other changes in utility service $8,304 - - - - $8,304
02 2.6212: Turn off equipment during breaks, reduce operating time $3,890 $200 $3,890
51,870
kWh
- - -
03 2.7261: Install timers and/or thermostats $6,769 $1,120 $4,220
56,260
kWh
- $2,549
-
MMBtu
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,155 $1,400 $1,658
22,110
kWh
$497
-
kW-mo/yr
- -
05 2.2511: Insulate bare equipment $1,730 $1,215 - - $1,730
-
MMBtu
-
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $17,295 $12,500 $13,309
177,450
kWh
$3,986
-
kW-mo/yr
- -
07 2.4231: Reduce the pressure of compressed air to the minimum required $684 $950 $526
7,016
kWh
$158
-
kW-mo/yr
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $2,570 $9,661 $2,054
27,393
kWh
$516
-
kW-mo/yr
- -
09 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $9,779 $78,580 $7,020
93,600
kWh
$2,759
-
kW-mo/yr
- -
TOTAL RECOMMENDED $53,176 $105,626 $32,677
435,699
kWh
$7,916
-
kW-mo/yr
$4,279
-
MMBtu
$8,304
TOTAL IMPLEMENTED $42,713 $26,096 $25,131
335,083
kWh
$4,999
-
kW-mo/yr
$4,279
-
MMBtu
$8,304
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs