| Assessment Year | 1989 |
|---|---|
| Principal Product | RUBBER SHEETING |
| NAICS |
n/a
|
| SIC | 3053: Gaskets, Packing, and Sealing Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,225
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $295,400 | 5,823,564 |
kWh
|
$0.051 |
| Natural Gas | $70,921 | 24,969 |
MMBtu
|
$2.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,175 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $38,175 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $14,280 | $1,400 |
$14,280
306,565
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,850 | $2,800 |
$7,850
168,523
kWh
|
|
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,840 | - |
$6,840
-
kWh
|
|
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,600 | $2,500 |
$4,600
156,800
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,360 | $660 |
$2,360
50,410
kWh
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,580 | $1,000 |
$1,580
49,238
kWh
|
|
| 07 | 2.2511: Insulate bare equipment | $665 | $270 |
$665
20,809
kWh
|
|
| TOTAL RECOMMENDED | $38,175 | $8,630 |
$38,175
752,345
kWh
|
||
| TOTAL IMPLEMENTED | $38,175 | $8,630 |
$38,175
752,345
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs